Type K Thermocouple (Temperature Measurement)
A temperature sensor consisting of two different metal wires (chromel versus alumel alloy) joined at one end; the temperature difference between this measuring point and the reference point generates a small, temperature-dependent thermoelectric voltage signal (the Seebeck effect), which is converted to a temperature value via a standardised table per NEN-EN-IEC 60584-1. Type K is popular for its wide measuring range (roughly -200 °C to +1260 °C), low cost and robustness, and in an electrotechnical context is used for thermographic calibration, monitoring transformer windings alongside or instead of PT100 sensors, and temperature control in power electronics and switchgear cabinets. Unlike a PT100 (resistance thermometer), a thermocouple delivers a direct voltage signal, which requires a separate cold-junction compensation in the measuring instrument for an accurate reading.
Bij het kalibreren van een thermografiecamera in een testlab gebruikt de technicus een type K-thermokoppel als referentietemperatuurbron, omdat dit een breed bereik en snelle respons biedt bij relatief lage kosten.
Een type K-thermokoppel rechtstreeks op een digitale multimeter aansluiten zonder koudelascompensatie en de afgelezen spanningswaarde direct als temperatuur interpreteren — zonder correcte referentiecompensatie ontstaat een structurele meetfout.